Back to blog
    Industrial Safety

    NOM 001 STPS safety conditions in industrial warehouses: Technical compliance guide

    Eng. SINE MéxicoJuly 22, 20267 min read

    NOM 001 STPS condiciones de seguridad en naves industriales: Guía técnica de cumplimiento

    In the industrial zones of Torreón, Saltillo, and Piedras Negras, the daily operation of manufacturing, foundry, and automotive assembly plants is relentless. Maintaining production pace demands that the physical infrastructure of the plant be at 100%. However, it is common for maintenance and plant managers to postpone critical infrastructure details, such as floor cracks, roof leaks, or ramps with non-compliant slopes, until a federal inspection arrives or, worse, a workplace accident occurs.

    Industrial welding NOM 001 STPS safety conditions is not a simple administrative procedure or a list of good intentions. It is a mandatory official Mexican standard that regulates the physical and structural conditions that all workplaces in the national territory must meet. Ignoring its guidelines not only exposes companies to millionaire fines from the Ministry of Labor and Social Welfare (STPS) but also compromises the physical integrity of operators and business continuity.

    In this technical guide, we will analyze in detail how to achieve NOM 001 STPS compliance in industrial buildings, breaking down structural requirements, safe design of traffic routes, employer obligations, and how to successfully pass a federal inspection using the best industrial engineering practices.


    Table of Contents


    1. Introduction to NOM-001-STPS-2008 and its impact on industrial buildings

    The standard NOM-001-STPS-2008 establishes the minimum safety requirements that workplace facilities must meet. Its main focus is preventive: it seeks to prevent accidents caused by structural failures, falls at the same or different levels, and deficiencies in personnel and machinery circulation routes.

    In the context of an industrial building, the impact of this standard is transversal. It affects everything from the foundation and the resistance of concrete floors to the quality of roof sheets, the inclination of loading ramps, and the distribution of pedestrian aisles. Deficient design or a lack of STPS industrial building maintenance not only increases the accident rate but also reduces the plant's operational efficiency by hindering internal logistical flows.


    2. Objective and scope of application of the standard in the Mexican industrial sector

    The objective of the standard is clear: to establish the safety conditions in industrial buildings and other workplaces so that they operate in an environment that does not pose risks to the life and health of workers.

    Its scope of application covers the entire national territory and applies to all workplaces regardless of their size or sector. However, in the manufacturing, maquiladora, and heavy industries (such as metalworking in the Comarca Lagunera), the standard acquires critical relevance due to the constant use of forklifts, overhead cranes, vertical rack storage, and the presence of chemical substances or high temperatures.


    3. Key employer obligations for NOM-001-STPS compliance

    To achieve proper NOM 001 STPS compliance, the employer or plant administrator must assume very specific legal and operational responsibilities:

    1. Maintain facilities in safe conditions: Perform periodic preventive and corrective maintenance on roofs, walls, floors, and traffic routes.
    2. Conduct annual visual inspections: Formally record the physical condition of the plant to detect anomalies (cracks, subsidence, detachments).
    3. Have a Structural Safety Report: Issued by an accredited expert or Verification Unit (or Conformity Assessment Body), especially after earthquakes, fires, or major structural modifications.
    4. Provide clean and safe service areas: Restrooms, dining rooms, and rest areas that meet basic hygienic conditions.
    5. Mark hazardous areas: Delimit pedestrian, vehicular, and storage areas in accordance with NOM-026-STPS.

    Engineer's Tip: Do not entrust the annual visual verification to an informal tour. Design a numbered technical logbook involving the maintenance manager and a representative of the Safety and Hygiene Commission (NOM-019-STPS). This demonstrates systematic and professional control to the STPS.


    4. Worker obligations in maintaining safety

    The success of industrial building structural safety does not rest solely on management; operators play a fundamental role. Under the standard, the employer's obligations NOM 001 are complemented by the following duties of workers:

    • Immediately inform the employer about any material damage or unsafe condition detected in the infrastructure (e.g., a pothole in the forklift aisle or a loose sheet on the roof).
    • Make proper use of the facilities and respect safety signage.
    • Participate in training sessions and civil protection and industrial safety brigades organized by the company.

    5. Specific structural requirements for industrial buildings: Roofs, walls, and floors

    The industrial building envelope must be designed and maintained to withstand operational loads and environmental forces (wind, rain, earthquakes) of the region where it is located.

    Roofs

    They must be constructed with materials that protect from the elements. They must have adequate slopes to prevent water accumulation (ponding) and correctly sized rainwater drainage systems. Translucent sheets must be protected or made of materials that prevent accidental falls during maintenance work at heights.

    Walls

    They must withstand wind loads and forces transmitted by overhead cranes or adjacent storage structures. They must have finishes that facilitate cleaning and maintenance, preventing the accumulation of dust and contaminants.

    Floors

    This is the element that suffers the most in a plant. Floors must be flat, level, free of open joints, cracks, or deformations that could destabilize forklifts or cause personnel to trip. Additionally, they must have appropriate coatings depending on the operation.

    Below is a comparative table of industrial floor coating solutions that facilitate compliance with the standard:

    Coating TypeWear ResistanceAnti-slip (NOM-001)Chemical ResistanceApprox. Cost per m² (MXN)Ideal Application
    Self-leveling EpoxyHighMedium (Requires additive)Excellent$450 - $750Electronic assembly, pharmaceutical, pedestrian walkways.
    Cementitious PolyurethaneExtremeHigh (Textured)Outstanding$800 - $1,400Food industry, foundries, constant washdown areas.
    Polyurethane PaintMediumLowMedium$250 - $400Aisle demarcation, light traffic warehouses.

    6. Safe design of traffic routes: Aisles, ramps, and stairs under the standard

    The safe transit of people and cargo vehicles is one of the most audited points during an STPS industrial facility inspection. Poor planning of these routes often leads to collisions and run-overs.

    Aisles and Circulation Routes

    Aisles designated for the transit of people and vehicles must have a width that allows for safe flow. An engineering rule derived from the standard is that the width of the aisles must be, at least, 60 centimeters wider than the width of the largest vehicle circulating through them, or have independent pedestrian aisles properly demarcated.

    Ramps

    Ramps for vehicle and pedestrian traffic must comply with maximum slopes to prevent rollovers or extreme fatigue:

    • For pedestrian traffic: Maximum slope of 10%.
    • For vehicle traffic: Maximum slope of 12% (or up to 15% if auxiliary braking systems and technical authorization are available).
    • They must have handrails if used for pedestrian traffic and the width is greater than 1.20 meters.

    Stairs

    Service and emergency stairs must comply with strict dimensions to ensure a safe and rapid descent in case of evacuation.

    Stair ElementMinimum DimensionMaximum DimensionRegulatory Observation
    Tread width25 cmNot specifiedMust be uniform throughout the flight.
    Riser height13 cm20 cmConstant height between steps.
    Stair width90 cm-Clear of any obstacles.
    Handrails / Guardrails90 cm high105 cm highMandatory if it has more than 4 steps.

    7. Ventilation systems and environmental conditions in production areas

    NOM-001-STPS establishes that workplaces must

    Do you need to carry out this work at your facility?

    More than 20 years executing industrial projects in Mexico. We respond in less than 24 hours.